Disc Spring Stack Design: Force, Travel & Height

When a single disc spring cannot carry the load or deliver the travel your assembly needs, you change the stack arrangement — not the disc count at random. The arrangement sets force, travel and stack height simultaneously, and friction plus part tolerance then consume part of that output before the stack reaches your target.

InputTargetOutputCalculated
Required force11.5 kN @ 0.60 mmDisc selectedDIN 2093 A 40
Max stack height26 mmArrangementn = 2 parallel, i = 1
Max bore / outer Ø42 mmFree stack height L05.40 mm (+0.15 / −0.00 worst case)
Temperature120 °CForce, loading / unloading≈12.03 kN / ≈11.33 kN
Load cycles10,000 (static/low-cycle)σOM @ 0.60 mm≈1,759 N/mm²

Scope: this guide covers stack calculation and verification only. Single-disc selection, alloys and coatings, and supplier qualification are separate topics — see the disc spring selection guide, spring materials, and custom precision springs.

Contents: Gate 1 Inputs · Gate 2 Disc & curve · Gate 3 Arrangement · Gate 4 Friction · Gate 5 Height & guide · Gate 6 Stress · Gate 7 Spec sheet · Worked example · FAQ

Disc Spring Stack CalculatorDIN 2092 / Almen–László force and σOM calculation with series–parallel stacks, friction band and height tolerance. Prefilled with the DIN 2093 A 40 worked example.
Disc geometry
Stack & working point
Envelope & acceptance criteria
Computed resultValue

Force values follow the DIN 2092 relationship with the Almen–László factors K₁–K₃. Friction is applied per sliding interface (n − 1 per series stage); seat friction and contact flattening are not modelled. σOM is the upper inner-edge stress at the specified working deflection. Allowable fatigue stress must be confirmed against the material-specific diagram supplied with the disc.

Gate 1 — Define the four inputs before you calculate anything

Four numbers decide every later step: required force F, required travel s, available axial height H, and available diameter Ø. Adding temperature and cycle count to those four defines whether the stack can survive, not just fit.

The four inputs: load, travel, available height, available diameter

Force only means something at a defined deflection, because disc springs are non-linear. Record F and s as a pair taken at the same working stroke. Then measure the pocket: a 40 mm disc in a 42 mm bore leaves 1.0 mm radial clearance per side, which sets your guiding options before you choose anything else.

Two conditions that decide everything: temperature and cycle count

Temperature and cycles set the stress ceiling (Gate 6). At 120 °C and 10,000 cycles you are designing a static clamp with thermal derating — not a room-temperature spring. If the same application ran millions of cycles, the allowable stress would drop by roughly 40% and change the disc choice, not just the count.

InputUnitHow to pull it from the assemblyCommon mistake
Required force FkNClamping or return force at working strokeEntering flattening load as working force
Required travel smmAxial stroke between installed and working positionUsing free height l0 as travel
Available height HmmAxial space at fully compressed stateConfusing free stack height with installed height
Available diameter ØmmBore ID or rod OD minus guide clearanceSizing on OD alone, ignoring guide wall
Decision gate: if one disc alone meets F, s, H and the stress limit, stop — you do not need a stack. If it cannot, continue to Gate 2.
Gate 1 errorWhy it happensFix
Flattening load used as working forceReading the catalogue peak at s = h0Read force at the real working deflection
Free height l0 treated as travell0 and h0 confusedDefine stroke between two positions
Bore envelope ignoredSizing by OD onlyRecord bore ID and rod OD up front
CheckpointAll four inputs written down with units, F and s paired at the same stroke, temperature and cycles recorded. No blanks before Gate 2.

Gate 2 — Choose the single disc and read its curve correctly

Pick a disc that fits your radial envelope and whose h0/t matches the behaviour your mechanism needs — then read its force at your working deflection, not at the catalogue's rated point.

What h0/t tells you about the load curve

h0/t sets the curve shape. Around 0.40 you get a near-linear, gently progressive curve. Near 0.75 you get a plateau. Above 0.80 you get an S-shaped curve with a force reversal. For a load that must stay inside a tolerance window, 0.40 is the safe choice.

Our example uses DIN 2093 Series A, size 40: De 40 / Di 20.4 / t 2.25 / l0 3.15 / h0 0.90 mm, so h0/t = 0.40.

Why you take the 75% point, not the flat point

DIN 2093 rates nominal force at 75% of cone height, not at flattening. Beyond 75%, force climbs steeply while edge stress spikes and contact geometry changes. Keep working deflection inside the 15%–75% band: below 15% the curve is unstable and seating effects dominate; above 75% you risk set and fatigue.

At 75% (0.675 mm) this disc gives ≈6.50 kN. At our actual working travel of 0.60 mm (66.7%) it gives ≈5.84 kN — a 10% difference that is easy to miss if you copy the rated value.

0.60 mm → 5.84 kN 75% → 6.50 kN flat 8.46 kN 15–75% working band 0 2 4 6 8 0 0.135 0.45 0.60 0.675 0.90 Travel s (mm) Force (kN)
Figure 1. The rated 75% point overstates force at your real working travel by about 10%, which is often the whole tolerance window.
h0/tCurve shapeGood forAvoid when
≈0.40Linear to slightly progressiveLoad that must track stroke (A 40 here)You need a flat plateau
≈0.75Near-horizontal plateauConstant preload over travel variationAxial space is tight
>0.80S-shaped, force reversalSnap-action, force limitingStroke crosses the inflection zone
Decision gate: confirm s@75% ≥ s and 0.15 ≤ s/h0 ≤ 0.75, then check whether F at your working deflection times a sensible n reaches target. If it takes n > 4, change disc size instead of stacking.
Gate 2 errorWhy it happensFix
Rated force used at working travelF@75% copied as working forceRecalculate at s, or interpolate the curve
l0 used as travell0 and h0 confusedUse s/h0 as the deflection fraction
Curve shape ignoredAssuming every disc is linearCheck h0/t before setting tolerance
Checkpoints@75% = 0.675 mm ≥ 0.60 mm; s/h0 = 66.7% inside the band; force at working travel recorded as 5.84 kN per disc.

Gate 3 — Set the arrangement: series, parallel, or combined

n (parallel) multiplies force; i (series) multiplies travel. Compute stack height with the exact formula, not count × thickness.

Parallel: multiply force, keep travel

n discs facing the same way multiply nominal force by n at unchanged deflection. Each extra disc adds one thickness t to the column and one sliding interface.

Two A 40 discs give 2 × 5.84 = 11.68 kN at 0.60 mm — +1.6% on an 11.5 kN target.

Series: multiply travel, keep force

Opposed discs multiply deflection by i at single-disc force, and grow stack height fast. Our 0.60 mm need is already covered by one disc's 0.675 mm at the 75% point, so i = 1.

Combined: parallel groups repeated in series

n discs per parallel packet, i packets in series. Always write both numbers on the drawing — "4 discs" is not a specification, "2×2" is.

The stack height formula you must use: L0 = i × (l0 + (n − 1) × t)

For n = 2, i = 1: L0 = 1 × (3.15 + 1 × 2.25) = 5.40 mm. (Series height is nominal i × l0; if your discs contact rim-to-rim, confirm the value against the supplier's stack drawing.)

Parallel force × n · travel × 1 n = 3, i = 1 Series force × 1 · travel × i n = 1, i = 3 Combined force × n · travel × i n = 2, i = 2 L0 = i × (l0 + (n − 1) × t) Nominal free stack height — never count × thickness
Figure 2. Direction, not count, decides whether you gain force or travel — and height grows either way.
ArrangementForceTravelL0Use when
Parallel (n, i=1)n × F1 × sl0 + (n−1)tForce short, space short
Series (n=1, i)1 × Fi × si × l0 (nominal)Travel short
Combined (n × i)n × Fi × si × (l0 + (n−1)t)Both short
Decision gate: if travel is short, solve i first (i ≥ s_req / s_disc), then n; otherwise set i = 1 and solve n while L0 ≤ H.
Gate 3 errorWhy it happensFix
Series and parallel swappedForce and travel multipliers confusedn scales force, i scales travel
Height as n × i × l0Every disc treated as a stageUse L0 = i × (l0 + (n−1)t)
Combined stack unlabelled"4 discs" written on BOMWrite n and i explicitly
Checkpointn = 2, i = 1, theoretical 11.68 kN at 0.60 mm, L0 = 5.40 mm ≤ 26 mm.

Gate 4 — Correct the calculated force for friction

Friction between discs makes the force you need to compress the stack higher than theory and the force it returns lower. Skipping this is why stacks hit target on paper and miss it on the bench.

Where friction comes from: sliding surfaces between discs

As discs deflect, their cones tilt and slide radially against neighbours and seats. A parallel packet of n discs has n − 1 sliding interfaces.

Friction factors by lubrication condition

Dry steel is worst, light oil is the common case, MoS₂ is best. At n = 2 there is one interface; at ≈3% it moves the 11.68 kN theoretical figure to ≈12.03 kN loading (×1.03) and ≈11.33 kN unloading (×0.97).

Loading versus unloading: the hysteresis band

The vertical gap between the two paths is the hysteresis band. Here it is (12.03 − 11.33) / 11.5 ≈ 6%. A tolerance window that ignores it will reject good parts or accept bad ones.

loading ≈12.03 kN unloading ≈11.33 kN loading path unloading path hysteresis ≈ 6% 0 Travel s (mm) → 0.60 Force (kN)
Figure 3. State both numbers on the drawing — an actuator must overcome the loading path, a return spring must survive the unloading path.
100% 130% 70% light oil, +3% / −3% per interface dry, ±6% per interface n = 1 2 3 4 5 6 Parallel disc count n Effective force vs n × F
Figure 4. Every added parallel disc buys less than the nominal step, so the fifth disc is worth roughly half the first.
Interfaces (n−1)LubricationEffect per interfaceWhat to expect
0 (n=1)AnyNegligibleMinimal hysteresis
1 (n=2)Light oil / grease≈3%≈6% band (this example)
2–3 (n=3–4)Light oil or MoS₂≈2–3%Band widens; check both bounds
≥4 (n≥5)DryHighAvoid; redesign instead
Decision gate: both F_load and F_unload must sit inside your force window. For 11.5 kN ±8% that is 10.58–12.42 kN; 12.03 and 11.33 pass. If not, reduce n, change disc, or improve lubrication.
Gate 4 errorWhy it happensFix
Only theoretical force quotedFriction skipped after n × FQuote load and unload values
Unloading path ignoredOnly peak clamp checkedVerify release force
Dry n≥4 stack estimated at 3%Light-oil rule reusedUse dry figures or redesign
Checkpoint12.03 kN loading, 11.33 kN unloading, ≈6% band, both inside 10.58–12.42 kN.

Gate 5 — Check stack height, tolerances and guide clearance

A stack that fits at nominal dimensions can still bind or bow. Verify worst-case height, then verify guiding.

Stack height tolerance: worst case vs RSS

L0 inherits the tolerance of every disc in the column. With n = 2, L0 = l0 + t, so ΔL0 sums Δl0 and Δt:

  • Worst case: ΔL0 = 0.10 + 0.05 = ±0.15 mm (all parts at the extreme).
  • RSS: ΔL0 = √(0.10² + 0.05²) = ±0.11 mm (random draw from a normal process).

Quote L0 = 5.40 +0.15/−0.00 mm on a height-limited drawing. (Tolerance inputs: use the class printed for your size — l0 ±0.10, t ±0.05 for this thickness group.)

Guiding: internal rod vs external sleeve

An internal rod runs through Di; an external sleeve surrounds De. Rods suit shaft-piloted assemblies; sleeves suit clean bores. Free-stacked parallel discs without guidance can cock and load unevenly.

Guide surface hardness and clearance by diameter

DeRadial clearance per sideGuide hardnessNote
≤25 mm0.15–0.30 mm≥58 HRC, groundGenerous clearance absorbs burrs
25–63 mm (e.g. 40)0.25–0.50 mm≥58 HRC, groundOur bore gives 1.0 mm available
63–125 mm0.40–0.80 mm≥58 HRC, groundAllow for thermal growth

Slenderness check: when L0/De needs guidance

L0/De = 5.40 / 40 = 0.135 — a short, stable column. As a working rule: below ≈0.5 no special measures; 0.5–1.0 guide the full length; above ≈1.0 add intermediate centring and check buckling explicitly.

Tolerance contributions l₀ per disc ±0.10 mm t per disc ±0.05 mm L₀ worst case ±0.15 mm L₀ RSS ±0.11 mm L₀ + worst-case tolerance = 5.55 mm ≤ H = 26 mm — accepted
Figure 5. Worst case tells you if it can physically fit; RSS tells you what you will actually measure in production.
self-supporting guide full length centring + buckling check 0 0.5 1.0 2.0 L₀/Dₑ = 0.135 Slenderness ratio L₀/Dₑ
Figure 6. Height is the constraint people check; slenderness is the one that actually bends the stack.
Decision gate: pass only if L0 + tolerance ≤ H, clearance sits in the table range, guide hardness meets spec, and L0/De is inside a zone you can guide.
Gate 5 errorWhy it happensFix
Nominal L0 onlyCatalogue treated as exactState L0 with tolerance
Unguided parallel stackAssuming a nearby shaft centres itAdd rod or sleeve to spec
Clearance near zeroMinimising playUse table clearance so burrs do not bind
CheckpointL0 = 5.40 +0.15/−0.00 mm ≤ 26 mm; L0/De = 0.135; clearance 0.25–0.50 mm; guide ≥58 HRC.

Gate 6 — Check stress and working point

Force and height can both pass while the steel yields or fatigues. Stress at your actual deflection is the third gate.

σOM, point II and point III in plain terms

σOM is the peak compressive stress at the upper inner edge (Di side) under deflection. Point II is where that edge starts to yield; point III is full plastic hinge formation, where load capacity flattens or collapses.

Using the DIN 2092 relationship with K1 = 0.686, K2 = 0.815, K3 = 1.363 for δ = 40 / 20.4 = 1.96:

σOM ≈ (4E/(1−μ²)) · (t²/(K1·De²)) · (s/t) · [K2(h0/t − s/2t) + K3]

At s = 0.60 mm: σOM ≈ 4,177 × 0.2667 × 1.580 ≈ 1,759 N/mm².

Stacking does not change single-disc stress — only total load and travel

A disc deflected 0.60 mm sees 0.60 mm whether it sits alone or in a stack of six. Stress is set by De, Di, t, h0 and s — never by n or i. Adding parallel discs raises stack force and raises nothing about per-disc life.

Allowable stress by cycle count and temperature

Typical published σOM guidance for quenched-and-tempered spring steel (50CrV4 class): static or low-cycle duty up to ≈1,900–2,000 N/mm²; ≈10⁴–10⁵ cycles around 1,200–1,400 N/mm²; 2 × 10⁶ cycles around 900–1,100 N/mm². At 120 °C, derate further and check relaxation. Always confirm against your supplier's fatigue diagram for the exact material and surface condition.

This is the trade-off most pages skip: at 1,759 N/mm² the 0.60 mm stack is fine for static clamping but marginal for 50,000 cycles at 120 °C. Holding stress near 1,300 N/mm² means dropping deflection to ≈0.44 mm, where each disc delivers only ≈4.39 kN — so the same 11.5 kN target then needs n = 3 (≈13.17 kN). Duty cycle, not force, drives the final count.

static / low cycle — 1,950 10⁴–10⁵ cycles — 1,300 2×10⁶ cycles — 1,000 0.44 mm → 1,314 0.60 mm → 1,759 0 1000 1300 1950 2400 0 0.40 0.50 0.60 0.70 0.90 Deflection ratio s/h₀ σOM (N/mm²)
Figure 7. Same disc, same force target: moving the working point 0.16 mm down the curve nearly halves the stress and adds a third disc to the stack.
Duty regimeTypical allowable σOMFitsAvoid
Static / low cycle (≤10⁴), ≤120 °C≈1,900–2,000 N/mm²Clamping, preload, occasional adjustmentSustained cycling
10⁴–10⁵ cycles, ≤120 °C≈1,200–1,400 N/mm²Actuation, brake/valve cyclingHigh-temp + high-cycle combined
2×10⁶ cycles≈900–1,100 N/mm²Endurance mechanismsCorrosive or elevated temp without derating
Gate 6 errorWhy it happensFix
"More discs = longer life"Stack capacity confused with unit stressEvaluate single-disc σOM at s
Static limits used for cyclingCatalogue yield used as design limitApply cycle-appropriate allowable
Temperature derating skipped20 °C values used at 120 °CDerate and check relaxation
CheckpointσOM ≈ 1,759 N/mm² at 0.60 mm accepted for static/low-cycle duty at 120 °C; if the duty is cyclic, re-run at ≈0.44 mm with n = 3.

Gate 7 — Output: the stack specification sheet

Compile geometry, counts, both force bounds, guiding and duty limits into one sheet so nobody reinterprets the stack.

The 12-line stack spec sheet

#FieldValue (this example)
1Disc standard & sizeDIN 2093 A 40 — De 40 / Di 20.4 / t 2.25 / l0 3.15 / h0 0.90
2Parallel count n2 per stage
3Series count i1 stage (2 discs total)
4Free stack height L05.40 mm, +0.15 / −0.00 worst case
5Theoretical force @ working point≈11.68 kN at 0.60 mm (66.7% h0)
6Loading force≈12.03 kN (1 interface, light oil)
7Unloading force≈11.33 kN (≈6% hysteresis)
8Working travel0.60 mm inside the 15–75% h0 band
9GuidingRod or sleeve, 0.25–0.50 mm per side, ≥58 HRC
10Material & surface50CrV4 class, oiled/coated; σOM ≈ 1,759 N/mm²
11Duty10,000 cycles static/low-cycle at 120 °C
12AcceptanceL0 in tolerance, load & unload force at 0.60 mm, burr-free edges

Five extra items a quote needs

Annual volume and release cadence · required certifications (ISO 9001, RoHS, REACH, mill certs) · packaging (trays/tubes, anti-corrosion wrap, single stack vs bulk) · sample quantity and lead time · target price tier at stated volume.

Next step: run your own numbers in the calculator, send the drawing and spec sheet, or ask for a stack review before you cut a PO.

INPUTS — F, s, H, Ø, temperature, cycles Gate 1 — can one disc do it at all?yes → stop Gate 2 — read force at working travel, check 15–75% band Gate 3 — solve i for travel, n for force, then L₀ Gate 4 — apply friction, check both loading and unloading fail → n↓ / lube Gate 5 — L₀ + tolerance ≤ H, clearance, L₀/Dₑ zone fail → n↓ / thinner Gate 6 — σOM against the allowable for duty and temperature fail → s↓ / new disc Gate 7 — emit the 12-line spec sheet and RFQ data RELEASE FOR PROTOTYPE SAMPLING Any gate that fails returns to the gate named on its right
Figure 8. The whole method on one page — use it as the review checklist in design and supplier conversations.

Worked example: from an 11.5 kN requirement to a validated stack

GateRule appliedResultStatus
1 InputsLock F, s, H, Ø, °C, cycles11.5 kN @ 0.60 mm, H ≤ 26, Ø ≤ 42, 120 °C, 10,000Pass
2 DiscA 40, h0/t = 0.40, read at working travel5.84 kN @ 0.60 mm; 6.50 kN @ 0.675 mmPass
3 Arrangementn = 2, i = 1; s/h0 = 66.7%11.68 kN theory; L0 = 5.40 mmPass
4 Friction1 interface × 3%12.03 / 11.33 kN, band ≈6%, inside 10.58–12.42Pass
5 Height & guideL0 + tol ≤ H; L0/De = 0.1355.40 +0.15/−0.00 ≤ 26; clearance 0.25–0.50Pass
6 StressσOM vs duty window≈1,759 N/mm² OK for static/low-cycle at 120 °CPass
7 Spec12-line sheet + 5 RFQ itemsReady for samples and BOM releasePass
Conclusion: PASS — n = 2, i = 1 of DIN 2093 A 40 meets 11.5 kN at 0.60 mm inside H ≤ 26 mm and Ø ≤ 42 mm, to be confirmed by prototype force testing. If duty rises to 50,000 cycles at 120 °C, re-run Gate 6: stress drives n to 3 at ≈0.44 mm travel.

Frequently asked questions

How do I stack disc springs to get more travel?

Put them in series (i > 1) so deflections add while force stays at single-disc level. Each stage adds its deflection to total travel and adds height proportionally.

How many disc springs can I stack in one column?

No fixed number — axial space, bore clearance, friction and slenderness (L0/De) set the ceiling. Keep L0 inside the envelope, check slenderness, and avoid high-n dry stacks.

How do I calculate the load of a Belleville spring stack?

Read single-disc force at your working deflection, multiply by n, then apply friction. Confirm you are multiplying the parallel count n, not the series count i.

Why is my calculated stack load higher than the measured load?

Because measured values are usually taken on the unloading path, where friction opposes recovery. Unlubricated surfaces, higher n, or reading the wrong leg of the cycle widen the gap.

What guide clearance and surface hardness does a disc spring stack need?

Radial clearance scaled to De (typically 0.25–0.50 mm per side for a 40 mm disc) against hardened, ground surfaces around ≥58 HRC. Tight clearance on soft guides binds and scores.

When should I use self-centering (wire-centered) disc spring stacks?

When free discs could shift laterally, cock, or bind in the housing during stroke. With a precision rod or sleeve and correct clearance, standard discs normally suffice.

Does stacking more discs increase fatigue life?

No. Stacking raises total force or travel; per-disc stress at a given deflection is unchanged. Life depends on s, σOM, material, surface, temperature and cycles.

What information do I need to quote a disc spring stack?

Required force and travel, axial and radial limits, temperature, cycles, and preferred n and i. Add annual volume, certifications, packaging and sample quantity.


An n = 2, i = 1 stack of DIN 2093 A 40 delivers ≈12.03 kN loading and ≈11.33 kN unloading around an 11.5 kN target at 0.60 mm, with L0 = 5.40 mm. Check the working point on the curve, the friction band, the height tolerance and the stress before you release the BOM.

Run the calculator · Send your drawing

Eva Lee

Eva Lee

Precision Spring Manufacturing Professional

As a manufacturing professional at Guangdong Hershey Spring (est. 2000), I help global clients solve complex engineering challenges. We specialize in custom precision springs (0.05mm to 25mm) for industries like automotive, electronics, and medical devices. I'm passionate about working with engineers to optimize designs and scale production.

Looking For A Trusted Spring Manufacturer?

Hershey Spring provides full-service custom spring manufacturing, from design and prototyping to mass production. Let our experts help you bring high-quality spring solutions to market.

No experience? No problem!

Recent Posts

Are You Looking For Custom Springs & Metal Components Manufacturer ?

Any Question? Write Down And Send Us